Omron G5 Series User Manual page 458

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

10 Troubleshooting and Maintenance
Alarm No.
Name
Main
Sub
27
0
Command Pulse
Frequency Error
2
Command Pulse
Multiplier Error
28
0
Pulse Regeneration
Error
29
0
Error Counter
Overflow
33
0
Interface Input
Duplicate Allocation
Error 1
1
Interface Input
Duplicate Allocation
Error 2
2
Interface Input
Function Number Error
1
3
Interface Input
Function Number Error
2
4
Interface Output
Function Number Error
1
5
Interface Output
Function Number Error
2
6
Counter Reset
Allocation Error
7
Command Pulse
Prohibition Input
Allocation Error
10 - 14
Cause
The command pulse input frequency
exceeded the value set in Command
Pulse Input Maximum Setting (Pn532) x
1.2.
The parameter setting for the command
pulse frequency or the electronic gear
ratio is not appropriate.
The value obtained by multiplying the
number of command pulses per 0.167
ms by the electronic gear ratio exceeded
approximately 3 Gpps (approximately
175 kpps for software versions earlier
than V1.10).
The command pulse input is sparse or
dense.
There is an erroneous count due to noise
contained in the command pulse input.
The pulse regeneration output frequency
exceeded the allowable limit.
The position error counter value
obtained with reference to the encoder
29
pulses exceeded +2
(536,870,912).
There is a duplicate setting in the input
signal (IN1, IN2 IN3, IN4, or IN5)
function allocations.
There is a duplicate setting in the input
signal (IN6, IN7, IN8, IN9, or IN10)
function allocations.
There is an undefined number
specification in the input signal (IN1, IN2,
IN3, IN4, or IN5) function allocations.
There is an undefined number
specification in the input signal (IN6, IN7,
IN8, IN9, or IN10) function allocations.
There is an undefined number
specification in the output signal (SO1 or
SO2) function allocation.
There is an undefined number
specification in the output signal (SO4)
function allocation.
The Error Counter Reset Input (ECRST)
pin was allocated to other than the input
signal S17.
The Pulse Prohibition Input (IPG)
function was allocated to other than the
input signal SI10.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Measures
Check the command pulse input.
• Set the electronic gear ratio as small
as possible in the range of 1/1,000 to
1,000 times.
• Check the command pulse input.
• Use the line driver interface if possible.
• Set Command Pulse Input Maximum
Setting (Pn532) to less than 1,000 and
enable the digital filter.
• Check the values set in Encoder
Dividing Numerator (Pn011) and
Encoder Dividing Denominator
(Pn503).
• To disable the detection, set Pulse
Regeneration Limit Setting (Pn533) to 0.
• Check to see if the Servomotor rotates
according to the position command.
• Check with the torque monitor to see if
the output torque is saturated.
• Adjust the gain.
• Maximize the values set in No.1
Torque Limit value (Pn013) and No.2
Torque Limit value (Pn522).
• Wire the encoder cable correctly.
Make sure that functions are correctly
allocated to these connector pins.