Rule for Linking Indications to a Group Indication
In a group indication, up to 4 indications can sequentially be linked logically. The indications 1 to 4 are always
linked successively as follows:
Indication 1 with Indication 2 = Indication 1/2
Indication 1/2 with Indication 3 = Indication 1/2/3
Indication 1/2/3 with Indication 4 = Group indication
Figure 8-36
Figure 8-37
SICAM Q100, 7KG95xx, Device Manual
E50417-H1040-C522-A4, Edition 03.2018
AND
INV
Example: Linking 4 Indications to a Group Indication
INV
Example: Linking 2 Indications to a Group Indication
8.3 Configuration of the Device
OR
AND
Group Indication 1
AND
Group Indication 1
8 Operation at Use of a PC