15.5.3

Recorder Parameters

Parameter
Average intervals - Frequency
Short term flicker
Long term flicker
Average interval - Voltage /
Unbalance / Harmonics
Record additional data (I, P, Q,
S etc.)
Recorder of average - Min
Recorder of average - Max
Harmonics parity
File generation every:
(corresponds to the setting of
the Average interval parame-
ter)
The created PQDIF files can be
downloaded via the user inter-
face or with the IEC 61850 pro-
tocol.
Recorded file type
Flicker lamp model
Tolerance unit
Tolerance number
Maximum recording interval
SICAM Q100, 7KG95xx, Device Manual
E50417-H1040-C522-A4, Edition 03.2018
Default Setting
Measurement recorder
10 s
10 min
2 h
10 min
no
no
no
Odd
24 h
PQDIF
230 V
Trend recorder
Percentage
Percentage: 3 % of primary
nominal voltage,
Numerical: 0.50 V
10 min
15 Operating Parameters
15.5 Recording and Reporting
Setting Range
fixed
fixed
fixed
30 s, 1 min, 10 min, 15 min, 30 min,
1 h, 2 h
no
yes
no
yes
no
yes
Even
Odd
All
At average interval
File generation
every:
30 s
1 h (fix)
1 min
2 h (fix)
10 min, 15 min,
2 h
30 min, 1 h or
4 h
2 h
6 h
12 h
24 h
PQDIF
CSV
All
230 V
120 V
Percentage
Numerical
1 % to 5 % in 1-% steps
0.2 V to 500.0 V
10 min, 30 min,
1 h, 2 h, 4 h, 6 h, 12 h, 24 h