Figure 6-2. Control Panel First-Level Menu Functions - Advanced Energy MDX II User Manual

Table of Contents

Advertisement

®
Advanced Energy
Use the MODIFY knob and the five unlabeled soft keys that are directly below the display to
select parameters and modify values. To have full access to the menu, the MDXII unit must
be in local control mode (the LOCAL LED will be lit).
Note: When the MDXII unit is in analog or serial mode, you can view all the menu items, but
you cannot modify any of the items or lock the unit. If you switch the MDXII unit to
analog mode while you are viewing an item in the menu, you are returned to the output
display screen immediately.
Press any of the soft keys when the output display screen is displayed to cause the top-level
menu to appear. The top-level menu contains five menu selections, which are shown in Figure
6-2 on page 6-4. Generally, pressing a top-level soft key causes a second level of menu
choices to display (for example, POWER and CURRENT display if you press the LIMITS soft
key).
LIMITS

Figure 6-2. Control panel first-level menu functions

As you press soft keys and move through the menu levels, the top line of the output display
screen usually continues to display until the last choice in that menu; then the top line is
replaced with information pertaining to the selection you can make. The three exceptions that
always display the first line are the analog input filtering feature, the transductor
calibration feature, and the arc density feature.
A parameter flashes if it can be modified; make such modifications with the MODIFY knob.
Pressing the ENTER soft key enters the modification into nonvolatile memory. You can press
the MODIFY knob at any time to cancel what you are doing (leave the parameter(s)
unchanged) and return to the output display screen.
If a fault exists, the soft keys are locked out until you clear the fault. Fault messages are listed
beginning on page 8-5.
Figure 6-3 on page 6-5 is a graphic representation of the control panel menu tree.
6-4
TIMERS
TARGET
Panel Connection, Controls and Indicators
ARC
MORE
5700262-P