ENVIRONMENTAL SPECIFICATIONS

Table 3-4. Climatic Specifications

Class 3K3
Operating
0°C to +40°C
+32°F to +104°F
Class 1K4
Storage
-25°C to +55°C
-13°F to +131°F
Class 1K4
Transportation
-25°C to +55°C
-13°F to +131°F
Note 1.
40°C is the maximum allowed. The average over 24 hours must not exceed 35°C.
Note 2.
Non-condensing
Note 3.
Maximum relative humidity when the unit temperature slowly increases, or when the
unit temperature directly increases from -25°C to +30°C
Note 4.
Maximum absolute humidity when the unit temperature directly decreases from +70°C
to +15°C

Table 3-5. Coolant Parameters for Air (Gas)

Temperature
0°C to 35°C
5700262-R
Temperature
Relative Humidity
Class 3K2
(Note 1)
20% to 80%
+6 g/m
Class 1K
35% to 95%
+1 g/m
Class 2K3
95%
60 g/m
Pollution degree 1. Cooling air should be free of corrosive
vapors and particles, especially conductive particles and
particles that could become conductive after exposure to
moisture. No condensation or icing.
Specifications
Class 3K3
(Note 2)
80 kPa to 106 kPa
3
3
to 23.5 g/m
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Class 3K3
80 kPa to 106 kPa
3
3
to 29 g/m
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Class 2K3
(Note 3)
66 kPa to 106 kPa
3 (Note 4)
660 mbar to 1060 mbar
(approximately 3265 m
above sea level)
Contamination