Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
2
ON
3
regulation
mode
4
power limit
5
current limit
5700262-R
Description
Pro
Sets dc output on; serial
control must be selected (see
Command 14).
Read back this value with
Command 161.
Sets the method of output
regulation (power, current,
voltage);
6 = power
7 = voltage
8 = current
Read back this value with
Command 154.
Specifies maximum output
power that can be delivered;
accepts a value of 0 to
maximum rated output: for
example, 1500 (15.00 kW,
decimal is implied), 3000
(30.00 kW)
Specifies maximum output
current that can be delivered;
accepts a value of 0 to 4800
(48.00 A for a 15k unit,
decimal is implied), 0 to
9600 (96.00 A for a 30k
unit)
Serial Port Connection, Controls and Indicators
MDXII Power Supplies
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
0
0
1
1
1
1
2
3
1
2
1
1
Pro
0
0
0
0