Advanced Energy
ELECTRICAL SPECIFICATIONS
Table 3-2. MDXII 15k and 30k Electrical Specifications
Input Voltages (internally
selected)
Input Current
0 to 15,000 W Output Power
Chassis per system
Output ripple voltage (% rms)
Output ripple frequency
0 to 30,000 W Output Power
Chassis per system
Output ripple voltage (% rms)
Output ripple frequency
Output Display Accuracy
Output Parameters
Table 3-3. MDXII 15k and 30k Output Voltage/Current Parameters
Tap
Max.
Number
Output
Voltage
tap 1
400 V
tap 2
500 V
tap 3
625 V
tap 4
800 V
tap 5
1000 V
tap 6
1250 V
3-2
Either 380/400/415 V ac ± 10% or
440/460/480 V ac ±10%, 50/60 Hz, three-phase Y or
maximum ground leakage current less than 3.5mA.
MDXII 15k model: 30 A maximum
MDXII 30k model: 60 A maximum
1
5
50 kHz
1
2
100 kHz
Within 1% of actual output level
Table 3-3 on page 3-2 indicates the maximum current
that can be produced at each tap. It also shows the range
of output voltages available at each tap, when the MDXII
unit is in voltage regulation (page 5-2).
Maximum Output Current
MDXII 15k
MDXII 30k
48.00 A
96.00 A
37.50 A
75.00 A
30.00 A
60.00 A
24.00 A
48.00 A
18.75 A
37.50 A
15.00 A
30.00 A