Advanced Energy MDX II User Manual page 208

Table of Contents

Advertisement

®
Advanced Energy
Table 9-1. User Port Signal Pins (Continued)
Signal
Return
Pin
Pin
18
9
19
21
37
22
37
23
9
24
9
9-12
Name
Signal
Type
15 V
ILK COM.D
digital
input
ARC.D
digital
output
EOTL.D
digital
output
V OUT.A
analog
output
P OUT.A
analog
output
User Port Connection, Controls and Indicators
Description
Use this signal to supply 15 V dc; it will
source a maximum of 100 mA.
This signal is a dedicated return to
internal system ground, then to chassis
ground, and finally to protective earth-
ground.
We recommend that all signals in the
interlock string be referenced to this pin.
This 0 to 15 V signal is held low for 10
to 20 ms whenever an arc is detected at
the MDXII output.
It will sink 35 mA. It is internally pulled
up to 15 V through a 10-k
its impedance is 100
.
This 0 to 15 V signal goes low when the
target-life counter reaches zero, thus
indicating that target life has ended
("end of target life").
This signal will sink 35 mA. It is
internally pulled up to 15 V through a
10-k
resistor, and its impedance is
100
.
This signal provides a fully buffered
signal, representing output voltage. Its
impedance is 100 . It will sink and
source 50 mA.
See Table 9-2 on page 9-15 for the
standard analog signal scalings.
This signal provides a fully buffered
signal, representing output power.
Its impedance is 100
source 50 mA.
See Table 9-2 on page 9-15 for the
standard analog signal scalings.
resistor, and
. It will sink and
5700262-R