Specifying Analog Input Filtering; Setting The Program Source; Specifying Clicks - Advanced Energy MDX II User Manual

Table of Contents

Advertisement

®
Advanced Energy

SPECIFYING ANALOG INPUT FILTERING

See "Analog Input Filtering" on page 5-17 for a description of this function.
MORE
CONFIG
1. At the top-level menu, press the MORE soft key.
2. Press the CONFIG soft key.
3. Press the FILTER soft key.
4. Use the MODIFY knob to specify the corner frequency of the low pass filter (0.5 Hz,
1.0 Hz, 2.0 Hz, 5.0 Hz, or Disabled).
5. Press the MODIFY knob to return to the output display screen.
Since volts, amperes, and kilowatt readings remain on the top line of the output display screen
while you are specifying the filtering level, you can quickly see how the readings are affected.

SETTING THE PROGRAM SOURCE

See "Program Source" on page 5-16 for a description of this function.
MORE
CONFIG
To specify where the MDXII unit looks for the parameters it uses to operate, follow these
steps:
1. At the top-level menu, press the MORE soft key.
2. Press the CONFIG soft key.
3. Press the PGM SRC soft key.
4. Press the HOST, LOCAL, or ANALOG soft key to toggle between INT and EXT for that
particular interface (you can set either program source for all three interfaces).
5. Press the ENTER soft key; you are returned to the output display screen automatically.

SPECIFYING CLICKS

See "Clicks" on page 5-17 for a description of this function
MORE
CONFIG
To increase or decrease the rate of change when you turn the MODIFY knob, follow these
steps:
1. At the top-level menu, press the MORE soft key.
2. Press the CONFIG soft key.
3. Press the CLICKS soft key.
4. Use the MODIFY knob to adjust the number of counts per click (1 through 20).
5. Press the ENTER soft key; you are returned to the output display screen.
6-14
FILTER
PGM SRC
CLICKS
Panel Connection, Controls and Indicators
5700262-P

Hide quick links: