Advanced Energy MDX II User Manual page 172

Table of Contents

Advertisement

®
Advanced Energy
Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
181
request
programmed
ramp
182
request
programmed
setpoint/
regulation
mode
183
request
programmed
run time
7-52
Description
Pro
Requests the programmed
ramp time (set with
Command 21) for the
specified step
Byte 1 = minutes
Byte 2 = seconds
*If fast ramp/run is
available, returning packet
contains the above 2 data
bytes plus 2 additional data
bytes.
Bytes 3 and 4 =
milliseconds.
Requests programmed
setpoint level (set with
Command 6) and whatever
method of output regulation
has been selected (set with
Command 3) for the
specified step
Bytes 1 and 2 =
setpoint level
Byte 3 = method of
regulation).
Requests programmed run
time (set with Command 23)
for the specified step
Byte 1 = hours
Byte 2 = minutes
Byte 3 = seconds
*If fast ramp/run is
available, returning packet
contains the above 3 data
bytes plus 1 data byte.
Byte 4 = milliseconds.
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
1
1
2 or
4*
1
1
3
1
1
3
or
4*
5700262-R
Pro
4
3
3
or
4*