Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
24
logic crc
25
recipe:
HALO,
steps, tap,
target
5700262-R
Description
Pro
Tells the MDXII unit to
calculate the logic software
checksum; during the
approximately 2 s it takes to
calculate the checksum, the
MDXII unit will not respond
to front panel or serial port
commands. Command 19
will not be accepted if the
MDXII unit is producing
output.
Read back this value with
Command 200.
Programs one recipe of up to
five steps
Byte 1:
bits 0, 1, 2 = accepts a
value of 0 to 5
bit 3, 4 = halo bit;
accepts a value of 0 to
5; If bit 3 is reset (0),
halo is deactivated. If
bit 4 is set (1), halo is
activated.
Byte 2 = the tap setting for
this recipe; accepts a value
of 1 to 6
Byte 3 = the target setting
for this recipe; accepts a
value of 1 to 8
Serial Port Connection, Controls and Indicators
MDXII Power Supplies
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
0
0
1
n/a
3
n/a
Pro
0
0
7-31