Advanced Energy MDX II User Manual page 167

Table of Contents

Advertisement

Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
163
request
config status
5700262-R
Description
Pro
Requests system
configuration status
1st status byte:
Bit 0 = Varc shutdown:
0 = no, 1 = yes
Bit 1 = ARC CHECK
active: 0 = no, 1 = yes
Bit 2 = C HOLD: 0 =
no, 1 = yes
Bit 3 = HALO active:
0 = no, 1 = yes
Bit 4 = Host program
source: 0 = internal,
1 = external
Bit 5 = Local program
source: 0 = internal,
1 = external
Bit 6 = Analog
program source: 0 =
internal, 1 = external
Bit 7 = HALO recipe:
0 = no, 1 = yes
2nd status byte:
Bit 0 = Control panel
present: 0 = no, 1 = yes
Bit 1 = Program source:
0 = internal,
1 = external
Bit 2 = Setpoint time
active: 0 = no, 1 = yes
Bit 3 = Tap source:
0 = internal,
1 = external
Bit 4 = User port C
HOLD active: 0 = no,
1 = yes
Bit 5 = Target life
active
Bit 6 = Unassigned
Bit 7 = Unassigned
Serial Port Connection, Controls and Indicators
MDXII Power Supplies
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
0
0
2
Pro
2
7-47

Hide quick links:

Advertisement

Table of Contents
loading