Advanced Energy MDX II User Manual page 210

Table of Contents

Advertisement

®
Advanced Energy
Table 9-1. User Port Signal Pins (Continued)
Signal
Return
Pin
Pin
31
9
32
9
33
36
36
37
9-14
Name
Signal
Type
LEVEL OUT.A
analog
output
10V REF.A
analog
output
HALO.D
digital
input
IN COM.D
digital
input
OUT COM.D
digital
output
User Port Connection, Controls and Indicators
Description
This signal provides a fully buffered
signal representing the MDXII unit's
programmed setpoint level. This signal
will source and sink 5 mA through a 2-
kW resistor. Its impedance is 100
See Table 9-2 on page 9-15 for the
standard analog signal scalings.
Vreg
Ireg
15k
0-2000 V
0-48.00 A
30k
0-2000 V
0-96.00 A
This signal provides an accurate 10 V
reference (10V ± 10 mV). Its
impedance is 100 .
Note: Limit current to 2 mA.
Use this 0 to 15 V signal to provide for
high accuracy at low output levels.
When this signal is low, the HALO
feature, if supported, is active (see page
5-19).
We recommend that you reference all
digital inputs, except the interlock
signals, to this pin.
This signal is used interchangeably with
OUT COM.D (pin 37). It is a dedicated
return to internal system ground, then to
chassis ground, and finally to protective
earth-ground.
This signal is used interchangeably with
IN COM.D (pin 36). It is a dedicated
return to internal system ground, then to
chassis ground, and finally to protective
earth-ground. All digital outputs should
be referenced to this pin.
.
Preg
0-15k
0-30k
5700262-R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents