Table B-6. Pin Descriptions
Pin
Name
3
SL OFF.D
4
SL ARC.D
5
SL FBK+.A
6
SL2 FAULT.D
7
SL2 FBK-.A
8
SL3 FBK+.A
B-4
Signal Type
output from the
It is used with pin 22 (SL ON.D) to turn
master unit, 0
the slave units on and off.
to 15V
SL ON.D
high (15 V)
low (0 V)
input to the
This 0 to 15 V input signal reports an arc
master unit, 0
detected by the slaves. The master then
to 15 V
handles the arc in the same manner it does
as a stand-alone unit. This signal is low
(0 V+/- 0.5 V) when an arc is being
reported by the slave. It is 15 V at all other
times.
input to the
This input signal is used by the master to
master unit, 0
determine and control total system output.
to 5 V or 0 to
It is an analog representation of the
10 V
current at the slave1 output. It is a fully
differential signal; pin 24 (SL1 FBK-) is
the return. It is scaled according to the
output power of the unit: 0 to 10 V for a
30 kW unit and 0 to 5 V for a 15 kW unit.
input to the
This 0 to 15 V input signal from the slaves
master unit, 0
reports a fault in slave2. A slave fault can
to 15 V
be bus high, bus low, overtemp, interlock,
or failure of the main contactor to close. A
high signal (15 V), indicates a slave fault;
a low signal (0 V+/- 0.5 V) indicates
normal operation.
return for pin
This is the return signal for pin 25.
25
input to the
This input signal is used by the master to
master unit, 0
determine and control total system output.
to 5 V or 0 to
It is an analog representation of the
10 V
current at the slave 3 output. It is a fully
differential signal; pin 27 (SL3 FBK-) is
the return. It is scaled according to the
output power of the unit: 0 to 10 V for a
30 kW unit and 0 to 5 V for a 15 kW unit.
Description
SL OFF.D
Status
high (15 V)
slave off
low (0 V)
slave on
5700262-R