Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
198
request s/w
revision
level—
mainframe
199
request s/w
revision
level—panel
200
request
software
checksum
201
request unit
on events
202
request
output on
events
203
request
overtemp
events
204
request idle
time
205
request run
time
5700262-R
Description
Pro
Requests the revision level
of the mainframe software;
returning packet will contain
3 ASCII characters: one
letter, followed by a two-
digit number
Requests the revision level
of the control-panel
software; returning packet
will contain 3 ASCII
characters: one letter,
followed by a two-digit
number.
Requests the logic software
checksum; this command
should be sent
approximately 2 s after
Command 19 is sent.
Requests how many times
input power to the MDXII
unit has been turned on
Requests how many times
output power has been
turned on
Requests how many
overtemperature faults have
occurred
Requests the amount of time
(in seconds) that input power
was turned on, but the
MDXII unit was not
producing output
Requests the amount of time
(in seconds) that the MDXII
unit was producing output
Serial Port Connection, Controls and Indicators
MDXII Power Supplies
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
0
0
3
0
0
3
0
0
2
0
0
4
0
0
4
0
0
4
0
0
4
0
0
4
Pro
3
3
2
4
4
4
4
4
7-55