Advanced Energy MDX II User Manual page 152

Table of Contents

Advertisement

®
Advanced Energy
Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
26
recipe: ramp
OR fast
ramp
7-32
Description
Pro
Programs ramp times for the
recipe programmed with
Command 20
Byte 1 = the step
number; accepts a
value of 1 to 5
Byte 2 = minutes of
ramp time; accepts a
value of 0 to 59 min
Byte 3 = seconds of
ramp time; accepts a
value of 0 to 59 s
*If fast ramp/run is
available, this command
requires 3 data bytes
Bytes 2 = seconds of
ramp time; accpets a
value of 0 to 59 min
Byte 3 = milliseconds
of ramp time; accepts a
value of 1 to 99 ms
Byte 3 has a granularity
of 10 ms for a range of
10ms to 990ms
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
n/a
3*
n/a
5700262-R
Pro
0