Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
164
request
setpoint/
regulation
mode
165
request
actual power
166
request
actual
voltage
167
request
actual
current
168
request
actual
power,
voltage,
current
7-48
Description
Pro
Requests output setpoint
level (set with Command 6)
and whatever method of
output regulation has been
selected (set with Command
3)
Bytes 1 and 2 =
setpoint level
Byte 3 = method of
output regulation)
Requests snapshot of output
power level at that instant:
for example, 1450 (14.50
kW, decimal is implied).
Requests snapshot of output
voltage level at that instant:
for example, 1250 (1250 V,
no implied decimal).
Requests snapshot of output
current level at that instant:
for example, 4800 (48.00 A,
decimal is implied).
Requests snapshot of output
power, voltage, and current
at that instant
Bytes 1 and 2 = power
level
Bytes 3 and 4 = voltage
level
Bytes 5 and 6 = current
level
Refer to Command 165, 166,
and 167 for format of
reported output values.
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
0
0
3
0
0
2
0
0
2
0
0
2
0
n/a
6
5700262-R
Pro
3
2
2
2
n/a

Hide quick links: