Advanced Energy MDX II User Manual page 170

Table of Contents

Advertisement

®
Advanced Energy
Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
172
request
current arc
trip level
173
request
voltage arc
trip level
174
request Arc-
Check
holdoff
175
request time
output on
176
request
ramp time
left
177
request run
time left
7-50
Description
Pro
Requests current level at
which the MDXII unit will
assume an arc exists and turn
off output (set with
Command 9); returning
packet will indicate value in
amperes (no decimal place
implied).
Requests how many volts
constitute an arc (set with
Command 10)
Requests the amount of time
the MDXII unit will wait
before it activates ARC
CHECK (set with Command
19)
Requests how much time has
elapsed since output power
was turned on
Byte 1 = number of
hours
Byte 2 = number of
minutes
Byte 3 = number of
seconds.
Requests how much ramp
time is left
Byte 1 = minutes left
Byte 2 = seconds left.
Requests how much run time
is left
Byte 1 = hours left
Byte 2 = minutes left
Byte 3 = seconds left.
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
0
0
2
0
0
2
0
0
2
0
0
3
0
0
2
0
0
3
5700262-R
Pro
2
2
2
3
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents