Environmental Specifications
Table A-4. MDXII 18P Climatic Specifications
Class 3K3
Operating
0°C to +40°C
+32°F to +104°F
Class 1K4
Storage
-25°C to +55°C
-13°F to +131°F
Class 1K4
Transportation
-25°C to +55°C
-13°F to +131°F
OPERATIONS AND FUNCTIONS
Contactor Closure
Compared to the MDXII 15k and 30k power supplies, the contactor closure operation in the
18P supply is independent of 'on' commands. This means you control contactor closure and
you must close the contactor before requesting or issuing an output 'on' command.
To close the contactor from an AE Bus or Profibus serial port, use Command 30. From the
User port, use pin 16 (CHOLD.D).
Note: Because most faults open the contactor, you must close the contactor after a fault occurs
to restore the supply to the ready state.
Deko/Varc
If your MDXII 18P unit features the Deko custom software, then the Varc detection time is
longer than typical. For more information about Deko, see "Deko" on page 2-24. For details
about detection times, see "Arc Delay and Density" on page 5-6.
5700262-R
Temperature
Relative Humidity
Class 3K2
(Note 1)
20% to 80%
+6 g/m
Class 1K
35% to 95%
+1 g/m
Class 2K3
95%
+60 g/m
Class 3K3
(Note 2)
80 kPa to 106 kPa
3
3
to 23.5 g/m
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Class 3K3
80 kPa to 106 kPa
3
3
to 29 g/m
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Class 2K3
(Note 3)
66 kPa to 106 kPa
3 (Note 4)
660 mbar to 1060 mbar
(approximately 3265 m
above sea level)
MDXII Power Supplies
Air Pressure
A-3