Advanced Energy MDX II User Manual page 147

Table of Contents

Advertisement

Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
18
filter level
19
Arc-Check
hold-off
5700262-R
Description
Pro
Specifies a factor by which
the analog signals
LEVELIN.A, RAMPIN.A,
voltage, and current readings
from the internal supply will
be filtered; this is a low pass
filter with variable corner
frequencies; accepts a value
of 0 to 127 (127 represents
the highest level of
filtering).
0 = filtering disabled
(i.e., all frequencies
allowed
1 = 0.5Hz corner
frequency
2 = 1.0Hz corner
frequency
3 = 2.0Hz corner
frequency
4 = 5.0Hz corner
frequency
Read back with Command
152.
Specifies the amount of time
the MDXII unit will wait
before attempting to
extinguish an arc by
activating the Arc-Check
circuitry; accepts a value of
5 to 500 (0.05 to 5.00 s,
decimal is implied).
Read back this value with
Command 174.
Serial Port Connection, Controls and Indicators
MDXII Power Supplies
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
1
1
1
2
2
1
Pro
0
0
7-27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents