Table 9-1. User Port Signal Pins (Continued)
Signal
Return
Pin
Pin
4
36
34
35
5
36
6
5700262-R
Name
Signal
Type
TARGET 0.D
digital
TARGET 2.D
input
TARGET 1.D
I REG.D
digital
input
P REG.D
digital
input
User Port Connection, Controls and Indicators
MDXII Power Supplies
Description
Use these signals to specify one of eight
possible targets. The MDXII
microprocessor uses this information to
keep track of the kilowatt usage for all
eight targets.
Note: An open input defaults to high (15
V); a shorted input is a low (0 V ±
0.5 V).
Target
No.
Pin 34
Pin 35
8
low
low
7
low
low
6
low
high
5
low
high
4
high
low
3
high
low
2
low
low
1
low
low
Use these signals to set the method of
output regulation (see page 5-1). An
open input defaults high to 15 V; a low
input is 0 V ± 0.5 V.
No method of output regulation is
selected if both P REG.D (pin 6) and
I REG.D (pin 5) are low. If you switch
the MDXII unit from local or host mode
to analog mode with this invalid
specification, the message "Invalid
Regulation Mode" displays on the
output display screen, and output power
will not come on. Simply specify a valid
method of regulation from the User port
and clear the message by pressing the
STOP switch or toggling pin 14 (RMT
OFF.D).
Pin 5
Pin 6
low
high
high
low
high
high
low
low
Pin 4
low
high
low
high
low
high
high
low
Reg. Mode
Ireg
Preg
Vreg
invalid
9-9