Table 8-3. AE Bus Command-Status Response (CSR) Codes (Continued)
Value
Meaning
12
Command not accepted because this feature is not available on your unit
(see "Understanding the Optional Software Features" on page 2-19)
13
Command not accepted because the control panel has priority
14
Invalid regulation mode
15
Invalid control mode (same as Value 1 above)
16
Target life consumed
17
Recipe is running
18
Ramping is underway
19
Recipe is active
99
Command not accepted because no such command exists
USER PORT OUTPUT SIGNALS
You can monitor the MDXII unit externally by means of output lines on the User port. Digital
signals are 0 to 15 V; analog signals are 0 to 10 V.
Table 8-4. User Port Status Indicators
Pin
Page
No.
1 & 20
9-7
2
9-8
3
9-8
21
9-12
22
9-12
23
9-12
24
9-12
25
9-13
30
9-13
31
9-14
5700262-R
Parameters to Monitor
Which target has been selected?
Is output enabled?
Has the setpoint level been reached?
Has an arc been detected?
Has the programmed target life ended?
What is the output voltage?
What is the output power?
What is the output current?
How much time remains on the target-life counter?
What is the setpoint level?
Troubleshooting and Customer Support
MDXII Power Supplies
8-13