Advanced Energy MDX II User Manual page 174

Table of Contents

Advertisement

®
Advanced Energy
Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
187
request
external
ramp
188
request arc
density
190
request xdcal
191
request pcalz
192
request pcalg
193
request lock
code
194
VHALO
Varc
7-54
Description
Pro
Requests the ramp time that
is specified through the User
port (external program
source) and therefore will be
active if the program source
for ramp time is set to
external; returning packet
contains 2 data bytes: 0 to
600 s.
*If fast ramp/run is
available: 50 to 1000 ms.
Requests how many voltage
arcs and current arcs
occurred in the previous
second
Bytes 1 and 2 = number
of voltage arcs
Bytes 3 and 4 =
number of current arcs
Requests the transductor
calibration value (set with
Command 50)
Requests the power
calibration zero value (set
with Command 51)
Requests the power
calibration gain value (set
with Command 52)
Requests the operator-
programmable code that
locks and unlocks the
control panel; each byte
contains one digit of the
five-digit code, high order
byte first.
Requests the Varc VHALO
trip level (set with
Command 71)
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
0
0
2
0
0
4
0
0
1
0
0
1
0
0
1
0
0
5
0
0
2
5700262-R
Pro
2
4
1
1
1
5
2

Hide quick links: