Operations; Slave Port; Table B-5. Output Parameters; Table B-6. Pin Descriptions - Advanced Energy MDX II User Manual

Table of Contents

Advertisement

Table B-5. Output Parameters

Max.
Power
Tap 1
(kW)
400 V
15
48.0
30
96.0
45
144.0
60
192.0
75
240.0
90
288.0
115
336.0
120
384.0

OPERATIONS

Slave Port

The master/slave interface, located on the rear panel, is a 37-pin, female, subminiature-D
connector that provides information from the MDXII master unit to the slave units, and
feedback from the slave units to the master unit. Its associated male connector, connector
shell, and jack post screws are included in the hardware kit.
Table B-6 on page B-3 provides quick-reference information about each pin. More detailed
signal descriptions begin on page 3-33 and information about making master/slave
connections is found on page 3-29. A ".A" appended to a pin name indicates an analog signal;
a ".D" appended to a pin name indicates a digital signal. A bar over a signal name indicates
that the signal is true when low.

Table B-6. Pin Descriptions

Pin
Name
1
SL TAPA.D
2
SL TAPC.D
5700262-R
Maximum Current for Each Tap
Tap 2
Tap 3
500 V
625 V
37.5
30.0
75.0
60.0
112.5
90.0
150.0
120.0
187.5
150.0
225.0
180.0
262.5
210.0
300.0
240.0
Signal Type
output from the
It is one of three signals that set the
master unit, 0
system output tap. It is used with pin 20
to 15V
(SL TAPB.D) and pin 2 (SL TAPC.D).
output from the
It is one of three signals that set the
master unit, 0
system output tap. It is used with pin 1
to 15V
(SL TAPA.D) and pin 20 (SL TAPB.D).
MDXII Power Supplies
Tap 4
Tap 5
800 V
1000 V
24.0
18.75
48.0
37.5
72.0
56.3
96.0
75.0
120.0
93.8
144.0
112.5
168.0
131.3
192.0
150.0
Description
Tap 6
1250 V
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
B-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents