Table 7-7. Definitions Of Profibus Upload Packet Status Bits - Advanced Energy MDX II User Manual

Table of Contents

Advertisement

®
Advanced Energy

Table 7-7. Definitions of Profibus Upload Packet Status Bits

Bit
Byte 0
0
1
2
3
4
5
6, 7
Byte 1
0
1
2
3
4
5
6
7
7-16
Function
setpoint status
OUTPUT.D status
end of target life (EOTL) status
joules status
joule mode
status of the Profibus interface
control mode status
A2D status if set A2D failure
or
general fault bit if any of the
implicit clear or explicit clear
faults occur if this bit is set
temperature status
interlock status
power status
bus fault status
contactor status
voltage arc (Varc) count status
current arc (Iarc) count status
Serial Port Connection, Controls and Indicators
Detail
0 = out-of-setpoint
1 = setpoint okay
0 = output is off
1 = output is on
0 = EOTL not reached
1 = EOTL reached
0 = joules not reached
1 = joules reached
0 = disable
1 = enable
active toggle bit serviced by inter-
face
10b = serial port
00b = User port
01b = control panel
'b' = binary (2 bits)
0 = A2D okay
1 = A2D failure
0 = temperature okay
1 = overtemperature event
0 = interlock okay
1 = interlock fault
0 = power okay
1 = momentary power failure
0 = bus okay
1 = bus fault high, low, or powerup
0 = contactor(s) closed
1 = contactor(s) open
0 = Varc count not reached
1 = Varc count reached
0 = Iarc count not reached
1 = Iarc count reached
5700262-R