Advanced Energy MDX II User Manual page 189

Table of Contents

Advertisement

Table 8-2. Panel LEDs and Fault Messages (Continued)
Problem Indicators
Passive
Control Panel Fault
Panel LED On
SETPOINT
"Out-of-setpoint"
OVERTEMP
"Overtemperature"
n/a
"Power Output Greater
Than Max. Allowed"
n/a
"Predefined Interrupt
Has Occurred"
5700262-R
Message
Output was turned
off because the
MDXII unit was not
able to produce
output equal to the
programmed setpoint
level in the amount
of time specified in
the out-of-setpoint
timer. Thus the out-
of-setpoint timer
expired.
The MDXII unit has
exceeded maximum
operating
temperature (Table
3-4 on page 3-3) or
an inverter module is
not plugged in
completely.
The unit exceeded
the maximum
allowed output
power for 1 s, so the
output was turned off
for safety reasons.
Potential software or
hardware problem.
Troubleshooting and Customer Support
Explanation
Suggested Action
Press the STOP switch to
clear the fault message.
Increase the setpoint
timer value or disable the
timer by setting it equal
to 0.
If the problem persists,
check your process
parameters for limiting
factors. That is, ensure
that your load impedance
matches the impedance
of the MDXII unit.
The fault message clears
itself when the unit cools.
If problem persists, call
AE Customer Support.
Turn the output back on.
The fault message clears
itself when you turn the
output back on.
If the message appears
again, contact AE
Customer Support.
Press the STOP switch to
clear the fault message.
Cycle power to the unit.
If the fault message
persists, call AE
Customer Support.
MDXII Power Supplies
8-9