Advanced Energy

Spacing Requirements

• The clearance between either side of the MDXII unit and the enclosure must be 76 mm
(3 in).
• The clearance between the top of the MDXII unit and the top of the enclosure must be
25 mm (1 in).
• No clearance is required between power supplies.
• The clearance between the rear of the MDXII unit and the enclosure must be 102 mm
(4 in), with adequate ventilation, which is explained on page 4-4.
1" (25 mm)
minimum clearance
to top of rack
0" (0 mm)
minimum clearance
between units

Figure 4-1. Top and side clearance requirements for MDXII units stacked in a cabinet

4-2
3" (76 mm)
minimum clearance from
enclosure to rack, each side