Advanced Energy
Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
50
transductor
calibration
value
51
power
calibration
zero value
52
power
calibration
gain
67
dual setpoint
68
dual recipe:
step,
setpoint,
regmode,
target
7-36
Description
Pro
Command used in
transductor calibration;
accepts a value of 0 to 255
Read back this value with
Command 190.
Power calibration zero
command; accepts a value of
0 to 255
Read back this value with
Command 191.
Power calibration gain
command; accepts a value of
0 to 255
Read back this value with
Command 192.
Specifies a unique setpoint
for the specified target pair:
1 and 3 or 2 and 4(if
supported by your MDXII
unit; see page 2-23).
Bytes 1 and 2 =
setpoint
Byte 3 = target (value
of 1 also specifies
setpoint for target 3)
Read back this value with
Command 141.
Lets you specify a dual
setpoint recipe (if supported
by your MDXII unit).
Byte 1 = step number
Bytes 2 and 3 =
setpoint
Byte 4 = regulation
mode
Byte 5 = target
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
1
1
1
1
1
1
1
1
1
3
n/a
1
5
n/a
1
5700262-R
Pro
0
0
0
n/a
n/a