Table 9-2. Standard User Port Analog Signal Scalings

V OUT.A
MDXII
0 - 10 V
15k
Notes 1 & 3
0 - 2000 V
unit
MDXII
0 - 10 V
30k
Notes 1 & 3
0 - 2000 V
unit
Note 1.
Some software configuration options will change this scaling (see "Understanding the
Optional Software Features" on page 2-19).
Note 2.
Invoking HALO will change this scaling.
Note 3.
Invoking VHALO will change this scaling.
Note 4.
On a 45 kW master/slave system I OUT.A is 0 - 192 A and P OUT.A is 0 - 60 kW.
5700262-R
I OUT.A
0 - 10 V
Notes 2 & 4
0 - 48.00 A
0 - 10 V
Notes 2 & 4
0 - 96.00 A
User Port Connection, Controls and Indicators
MDXII Power Supplies
LEVEL IN.A
P OUT.A
LEVEL OUT.A
0 - 10 V
0 - 10 V
Same scaling as
Notes 2 & 4
0 - 15 kW
V OUT.A,
I OUT.A, or
P OUT.A based
on the regula-
tion mode
0 - 10 V
0 - 10 V
Same scaling as
Notes 2 & 4
0 - 30 kW
V OUT.A,
I OUT.A, or
P OUT.A based
on the regula-
tion mode
Notes 2 & 3
Notes 2 & 3
9-15