Using The Ascii Feature; Calibrating The Transductor; Displaying User Input Character String - Advanced Energy MDX II User Manual

Table of Contents

Advertisement

®
Advanced Energy

USING THE ASCII FEATURE

See "ASCII" on page 5-18 for a description of this feature.
MORE
OPTIONS
To enable ASCII host communications, follow these steps:
1. At the top-level menu, press the MORE soft key.
2. Press the OPTIONS soft key.
3. Press the ASCII soft key.
4. Turn the MODIFY knob to select YES or NO.
5. Press the ENTER soft key; you are returned to the output display screen automatically.

CALIBRATING THE TRANSDUCTOR

See "Transductor Calibration" on page 5-18 for a description of this function.
MORE
SERVICE
1. Turn output on, select current regulation, and set the setpoint to zero.
2. At the top-level menu, press the MORE soft key.
3. Press the SERVICE soft key.
4. Press the DEBUG soft key.
5. Press the CALIB soft key.
6. Press the XDCAL soft key.
7. Specify a transductor calibration factor (0 through 255) with the MODIFY knob until the
"Amps" reading on the top line of the display is zero (start with a calibration factor of zero
and slowly work up until the "Amps" reading goes to zero).
8. Press the MODIFY knob to return to the output display screen.

DISPLAYING USER INPUT CHARACTER STRING

See "Memo Function" on page 5-21 for a description of this function.
MORE
SERVICE
1. At the top-level menu, press the MORE soft key.
2. Press the SERVICE soft key.
3. Press the MORE soft key.
4. Press the MEMO soft key.
6-16
ASCII
DEBUG
CALIB
MORE
MEMO