Table 9-1. User Port Signal Pins (Continued)
Signal
Return
Pin
Pin
25
9
26
10
27
10
30
9
5700262-R
Name
Signal
Type
I OUT.A
analog
output
RAMP IN.A
analog
input
LEVEL IN.A
analog
input
KWH OUT.A
analog
output
User Port Connection, Controls and Indicators
MDXII Power Supplies
Description
This signal provides a fully buffered
signal, representing output current from
your unit; maximum current depends on
which tap is selected).
Its impedance is 100
. It will sink and
source 50 mA.
See Table 9-2 on page 9-15 for the
standard analog signal scalings.
Use this signal to program ramp time
when ANALOG has been selected on
the control panel.
If fast ramp/run is available, ramps of
50 to 1000 ms are available.
Use this signal to program the output
level when ANALOG has been selected
on the control panel.
See Table 9-2 on page 9-15 for the
standard analog signal scalings.
Vreg
Ireg
15k
0-2000 V
0-48.00 A
30k
0-2000 V
0-96.00 A
HALO 15k
0-2000 V
0-4.8 A
HALO 30k
0-2000 V
0-9.6 A
This signal provides a fully buffered 0 to
10 V signal representing the amount of
kilowatt-hours remaining in the target
life: 10 V±1% = 15,000 kWh for the 15k
unit and 30,000 kWh for the 30k unit
(updated in 1-kWh increments). This
signal will source and sink 5 mA
through a 2-kW resistor. Its impedance
is 100
.
Preg
0-15k
0-30k
0-1.5kW
0-3.0kW
9-13