Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
6
setpoint
7
tap set
8
arc delay
9
Iarc trip
level
7-22
Description
Pro
Specifies the output setpoint
level for whichever method
of output regulation has been
selected; accepts a value for
a 15k unit (for example) of 0
to 1500 (15.00 kW, decimal
is implied), 0 to 4800 (48.00
A, decimal is implied), or 0
to maximum output voltage
for the selected tap (no
implied decimal).
Read back this value with
Command 164.
Specifies one of six possible
tap settings; accepts a value
of 1 to 6.
Read back this value with
Command 153.
Specifies how long the
MDXII output will remain
turned off after an arc has
been sensed—use 0 (zero) if
minimum delay is desired;
accepts a value of 0 to 1000
ms (no implied decimal).
Read back this value with
Command 171.
Specifies current level at
which the MDXII unit will
assume an arc exists and turn
off output; accepts a value of
0 to 700 (70.0 A, decimal is
implied); for units with an
input of 460/480V, accepts a
value of 0 to 600 (0 to
60.0 A).
Read back this value with
Command 172.
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
2
2
1
1
1
1
2
2
1
2
2
1
5700262-R
Pro
0
0
0
0