Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
√
142
request dual
recipe
setpoint
√
143
request Iarc
count limit
√
144
request Varc
count limit
√
145
request joule
setpoint
146
request
power limit
147
request
voltage limit
148
request
current limit
√
152
request filter
level
√
153
request tap
√
154
request
regulation
method
5700262-R
Description
Pro
√
Requests the dual setpoint
recipe (set with Command
68)
Bytes 1 and 2 =
setpoint side A
Byte 3 = regulation
mode
Bytes 4 and 5 =
setpoint side B
Byte 6 = regulation
mode
√
Requests the Iarc count limit
(set with Command 69)
√
Requests the Varc count
limit (set with Command 69)
√
Request the joule setpoint
(set with Command 70)
√
Requests the maximum
output power limit (set with
Command 4)
√
Requests the maximum
output voltage limit
√
Requests the maximum
output current limit (set with
Command 5)
√
Requests the filter factor for
the analog signals (set with
Command 18)
√
Requests tap setting (set
with Command 7)
√
Requests method of output
regulation (set with
3
Command
)
Serial Port Connection, Controls and Indicators
MDXII Power Supplies
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
1
6
0
0
2
0
0
2
0
4
n/a
0
n/a
n/a
0
n/a
n/a
0
n/a
0
0
1
0
0
1
0
0
1
Pro
2
2
2
2
2
1
1
1
7-39