Advanced Energy MDX II User Manual page 150

Table of Contents

Advertisement

®
Advanced Energy
Table 7-9. AE Bus and Profibus Communications Commands (Continued)
Command
Used By
AE
23
recipe run or
fast run
7-30
Description
Pro
Programs run times for the
recipe programmed with
Command 20
Byte 1 = the step
number; accepts a
value of 1 to 5
Byte 2 = hours of run
time; accepts a value of
0 to 99
Byte 3 = minutes of run
time; accepts a value of
0 to 59
Byte 4 = seconds of run
time; accepts a value of
0 to 59
*If fast ramp/run is
available, this command
requires 4 data bytes plus 1
data byte
Byte 5 = milliseconds
of ramp time; accepts a
value of 0 to 99
(representing 0 to 990
ms)
Read back this value with
Command 183.
Serial Port Connection, Controls and Indicators
Host Data
ResponseData
Bytes
Bytes
AE
Pro
AE
4
n/a
1
or
5*
5700262-R
Pro
n/a

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents