9 REAL MODE/VIRTUAL MODE SWITCHING AND STOP/RE-START

9.2 Switching from the Virtual Mode to Real Mode

9.2.1 Switching by user

Table 9.4 Check Items List for VIRTUAL Mode to REAL Mode Switching
Check sequence
1

9.2.2 Switching by the operating system software

There are following methods for switching from the virtual mode to real mode.
• Switching by user
• Switching automatically by the operating system software
(1) When the virtual mode to real mode switching is requested (M2043 ON
the item in Table 9.4 is checked. If normal, it switches to the real mode.
(Confirm the check items in Table 9.4 for the switching from virtual mode to real
mode, and execute with all normal state.)
(
2) The real mode/virtual mode switching error detection flag (M2045) turns on at the
error detection, and the error code is stored in the real mode/virtual mode
switching error information (SD504 to SD506). (Refer to APPENDIX 2.7)
Check item
• Are all axes (Virtual axis and real mode axis)
stopped? (M2001 to M2032 : OFF)
(1) If the following items are detected in the virtual mode operation, the operating
system software automatically switches back to the real mode.
• The forced stop is input.
• PLC ready flag (M2000) turns off.
• When "Return to Real Mode" is set as an operation on servo error, the servo
error detection signal (M2408+20n) turns on even if 1 axis.
(2) The error code is stored in the real mode/virtual mode switching error information
(SD504 to SD506) at the switching back from virtual mode to real mode. However,
the real mode/virtual mode switching error detection flag (M2045) does not turn
on.
Normal condition Abnormal condition
9 - 5
OFF
ON even if 1 axis
OFF),