4 POSITIONING DEDICATED SIGNALS
(21) Control loop monitor status (M2272 to M2303)
When using the fully closed loop control servo amplifier, this signal is used to
check the fully closed loop control/semi closed loop control of servo
amplifier.
• ON .......... During fully closed loop control
• OFF .......... During semi closed loop control
It can be changed the fully closed loop control/semi closed loop control of
servo amplifier in the Motion controller by the control loop changing
command ON/OFF.
Fully closed loop
control change
Control loop
OFF
changing command
(M3218+20n)
Control loop
OFF
monitor status
(M2272+n)
The Control loop monitor status list is shown below.
Axis No.
Device No.
1
M2272
2
M2273
3
M2274
4
M2275
5
M2276
6
M2277
7
M2278
8
M2279
............................... Command signal
ON
ON
Axis No.
Device No.
Axis No.
9
M2280
17
10
M2281
18
11
M2282
19
12
M2283
20
13
M2284
21
14
M2285
22
15
M2286
23
16
M2287
24
(Note): The range of axis No.1 to 8 is valid in the Q172DCPU.
4 - 50
Semi closed loop
control change
Device No.
Axis No.
Device No.
M2288
25
M2296
M2289
26
M2297
M2290
27
M2298
M2291
28
M2299
M2292
29
M2300
M2293
30
M2301
M2294
31
M2302
M2295
32
M2303