Appendix 2.3 Servo Program Setting Errors (Stored In Sd517) - Mitsubishi Electric Q Series Programming Manual

Motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

APPENDICES

APPENDIX 2.3 Servo program setting errors (Stored in SD517)

Error code
Error name
stored in SD517
Parameter block No.
1
setting error
Address (travel
value) setting error
(Except the speed
control and
speed/position
control.)
(Setting error for
(Note)
n03
linear axis at the
helical-interpolation.)
Command speed
error
4
Dwell time setting
5
error
M-code setting error The M-code is outside the range
6
Torque limit value
7
setting error
(Note-1): When the "speed control 10
[degree/min].
The error codes, error contents and corrective actions for servo program setting errors
are shown in Table 2.1.
In the error codes marked with "Note" indicates the axis No. (1 to 32).
Table 2.1 Servo program setting error list
Error contents
The parameter block No. is outside
the range of 1 to 64.
(1) The address is outside the
setting range at the positioning
start for absolute data method.
Unit
Address setting range
0 to
degree
35999999
(2) The travel value is set to
-2147483648 (H80000000) at
the positioning start for
incremental data method.
(1) The command speed is outside
the range of 1 to the speed
limit value.
(2) The command speed is outside
the setting range.
Unit
Speed setting range
1 to
mm
600000000
1 to
inch
600000000
1 to
degree
2147483647
1 to
PLS
2147483647
The dwell time is outside the
range of 0 to 5000.
of 0 to 32767.
The torque limit value is outside
the range of 1 to 1000.
multiplier setting for degree axis" is set to "valid", the setting range is 0.01 to 21474836.47
Error processing
Execute the servo program
with the default value "1" of
parameter block.
(1) Positioning control does
not start. (All interpolation
control at the interpolation
control.)
(2) If the error is detected
during the speed-
–5
10
switching control or
[degree]
constant-speed control, a
deceleration stop is
made.
(3) If an error occurs in one
servo program, all servo
programs do not execute
during the simultaneous
start.
(1) Positioning control does
not start if the command
speed is "0" or less.
(2) If the command speed
exceeds the speed limit
value, control with the
speed limit value.
-2
10
[mm/min]
-3
10
[inch/min]
-3
10
[degree
/min]
(Note-1)
[PLS/s]
Control with the default value
"0".
Control with the torque limit
value of the specified
parameter block.
APP - 10
Corrective action
Set the parameter block No.
within the range of 1 to 64.
(1) If the control unit is
[degree], set the address
within the range of 0 to
35999999.
(2) Set the travel value within
31
the range of "0 to (2
-1)".
Set the command speed within
the range of 1 to the speed
limit value.
Set the dwell time within the
range of 0 to 5000.
Set the M-code within the
range of 0 to 32767.
Set the torque limit value
within the range of 1 to 1000.