Gateway Settings

Click Gateway Configuration ->
screen. Use the Gateway Settings screen to view and modify processing and forwarding
data from the serial ports to the Ethernet interface.

Fig. 82: Connect Gateway - Serial Gateway [1,2] Settings Screen

Serial Gateway [1,2] Settings

Gateway Mode: Select the mode of operation for this gateway.
Inactive : This port is not active. Settings are not displayed.
Raw TCP Server: The port protocol is basic TCP.
Modbus TCP Server: The port protocol is MODBUS over TCP.
COM Port Binding: Select the port for this gateway (Unassigned, DATA 1, DATA 2).
Unassigned : The gateway is not active.
DATA1: The gateway is assigned to port DATA1.
DATA2: The gateway is assigned to port DATA2.

Serial Gateway [1,2] Data Packing

Packet length : Enter the Ethernet packet length (up to 1024) when packing serial data.
Force Transmit (msec): Enter the maximum time period (0-65535 milliseconds) to
collect serial data before forwarding the data over the Ethernet port. This function can be
used to aggregate serial data and forward it over the TCP/IP in a single Ethernet frame.
The buffered data is forwarded immediately if the receive data buffer reaches maximum
capacity (1 KB).