Redline RDL-3000-RMD Product Manual

Broadband wireless systems, radio module

Advertisement

Quick Links

RDL-3000 M2M Solutions
1
Product Overview ................................................................... 5
2
Conditions of Use ................................................................... 6
3
Module Installation and Service ............................................ 8
4
Final Product Requirements ................................................ 10
70-00184-06-00a
RDL-3000 Family
Broadband Wireless Systems
RDL-3000-RMD
Radio Module
Product Manual
Proprietary Redline Communications © 2013
Page
1
of 20
December 9, 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RDL-3000-RMD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Redline RDL-3000-RMD

  • Page 1 Broadband Wireless Systems RDL-3000-RMD Radio Module Product Manual Product Overview ..............5 Conditions of Use ..............6 Module Installation and Service ..........8 Final Product Requirements ..........10 70-00184-06-00a Proprietary Redline Communications © 2013 Page of 20 December 9, 2013...
  • Page 2 All rights reserved December 9, 2013. The information in this document is proprietary to Redline Communications Inc. This document may not in whole or in part be copied, reproduced, or reduced to any medium without prior consent, in writing, from Redline Communications Incorporated.
  • Page 3: Table Of Contents

    Power and EIRP Results (MIMO Operation) ........... 17 Operation in the 3450-3650 MHz Band ............17 Operation in the 3650-3675 MHz Band ............17 Industry Canada Notices: Deployment in Canada: ........18 70-00184-06-00a Proprietary Redline Communications © 2013 Page of 20 December 9, 2013...
  • Page 4 Table 2: FCC - RDL-3000-RMD EIRP Measurement Results for 5 MHz ......11 Table 3: FCC - RDL-3000-RMD EIRP PSD Measurement Results for 5 MHz ....12 Table 4: FCC - RDL-3000-RMD EIRP Measurement Results for 10 MHz ...... 13 Table 5: FCC - RDL-3000-RMD EIRP PSD Measurement Results for 10 MHz ....
  • Page 5: Product Overview

    This is afterwards referred to as the 'final product'. The final product may be designed and manufactured by Redline or a licensed third party. Frequency settings within the specified frequency ranges are software keyed to be compliant with specific regulatory agency requirements in the region of deployment.
  • Page 6: Conditions Of Use

    Any operation or use of these modules in any manner not expressly specified within this manual or approved in writing by Redline (or its agents) is expressly forbidden and voids the users right to operate the module. This includes, but is not limited to, any modification of the module hardware or software, installation of the module in a non approved enclosure, and use with non approved antennas.
  • Page 7: Product Labeling

    Information labels are applied to the final product. The final product features a label on the outside surface listing the registration number for the enclosed module. Do not to remove any labels from the module or the final product. 70-00184-06-00a Proprietary Redline Communications © 2013 Page of 20 December 9, 2013...
  • Page 8: Module Installation And Service

    The modules must be installed only by trained professional technicians authorized by Redline or its agents. The module must be installed only into an approved enclosure (see Conditions of Use) and only at an approved manufacturing facility or service depot.
  • Page 9: Safety Precautions

    Safety Code 6, obtainable from Health Canada’s website and information from the websites listed below: http://www.gpo.gov/fdsys/pkg/CFR-2009-title47-vol1/pdf/CFR-2009-title47-vol1-sec2- 1091.pdf http://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet 65c.pdf http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php Refer also to the regulatory statements included in this document. 70-00184-06-00a Proprietary Redline Communications © 2013 Page of 20 December 9, 2013...
  • Page 10: Final Product Requirements

    Frequency Bands Operation of the final product requires an FCC specific software 'key' that is available exclusively from Redline. This key restricts device operation to the IC 3675-3700 MHz band. The professional installer and operator can not modify or otherwise circumvent these operational restrictions.
  • Page 11: Operation In The 3675-3700 Mhz Band

    RDL-3000 FAMILY RDL-3000-RMD PRODUCT MANUAL 4.1.4 Operation in the 3675-3700 MHz Band Table 2: FCC - RDL-3000-RMD EIRP Measurement Results for 5 MHz Peak output Maximum Frequency, Power EIRP limit, Port Modulation power, Antenna setting dBm/25 MHz dBm/5 MHz Gain, dBi 3677.5...
  • Page 12: Table 3: Fcc - Rdl-3000-Rmd Eirp Psd Measurement Results For 5 Mhz

    RDL-3000 FAMILY RDL-3000-RMD PRODUCT MANUAL Table 3: FCC - RDL-3000-RMD EIRP PSD Measurement Results for 5 MHz Peak output EIRP limit, Maximum Frequency, Power Port Modulation power, dBm/25 Antenna setting dBm/5 MHz Gain, dBi 3677.5 17.60 12.40 3685 17.33 12.67 BPSK 3697.5...
  • Page 13: Table 4: Fcc - Rdl-3000-Rmd Eirp Measurement Results For 10 Mhz

    RDL-3000 FAMILY RDL-3000-RMD PRODUCT MANUAL Table 4: FCC - RDL-3000-RMD EIRP Measurement Results for 10 MHz Peak output EIRP limit, Maximum Frequency, Power Port Modulation power, dBm/25 Antenna setting dBm/5 MHz Gain, dBi 3680 22.22 17.78 3685 22.33 17.67 BPSK 3695 22.04...
  • Page 14: Table 5: Fcc - Rdl-3000-Rmd Eirp Psd Measurement Results For 10 Mhz

    RDL-3000 FAMILY RDL-3000-RMD PRODUCT MANUAL Table 5: FCC - RDL-3000-RMD EIRP PSD Measurement Results for 10 MHz Peak output EIRP limit, Maximum Frequency, Power Port Modulation power, dBm/25 Antenna setting dBm/5 MHz Gain, dBi 3680 14.33 15.67 3685 14.38 15.62...
  • Page 15: Fcc Notices

    To satisfy FCC RF exposure requirements for RF transmitting devices, the following distances should be maintained between the antenna of this device and persons during device operation: Table 6: FCC - RDL-3000-RMD Recommended Safe Distances 50 cm (19.7 in) or more 3675 To ensure compliance, operation at closer than these distances is not recommended.
  • Page 16 4. Changes or modifications not expressly approved by Redline Communications could void the user’s authority to operate the equipment. 5. Do not operate an RDL-3000-RMD outdoor transceiver until you have confirmed the FCC specific options key is loaded and active (operating range restricted to 3675- 3700 MHz).
  • Page 17: Deployment In Canada

    Operation of the final product requires a software 'key' that is available exclusively from Redline. This key restricts device operation to the IC 3450-3650 MHz or 3650-3675 MHz band. The professional installer and operator can not modify or otherwise circumvent these operational restrictions.
  • Page 18: Industry Canada Notices: Deployment In Canada

    Règlements qui régissent le fonctionnement IC dans la bande 3450-3700 MHz sont soumises à autorisation en vertu du paragraphe 4 (1) de la Loi sur la radiocommunication. 70-00184-06-00a Proprietary Redline Communications © 2013 Page of 20 December 9, 2013...
  • Page 19 Réglementation régissant le fonctionnement d'IC dans les états de bande 3450-3675 MHz que les transmissions des stations de base sont limités à un maximum de puissance d'émission de 1 Watt / MHz (pire de crête). 70-00184-06-00a Proprietary Redline Communications © 2013 Page of 20 December 9, 2013...
  • Page 20 302 Town Centre  Markham, Ontario  Canada  L3R 0E8 www.rdlcom.com 70-00184-06-00a Proprietary Redline Communications © 2013 Page of 20 December 9, 2013...

This manual is also suitable for:

Rdl-3000 series

Table of Contents