7.1

Modify CIR/PIR Settings for Services on STID Links

IMPORTANT NOTICE: Changing CIR / PIR for Services on STID Link Templates
Failure to follow the procedures in this section when changing the CIR / PIR
settings on services associated with STID link templates will cause LOSS OF
COMMUNICATIONS to all subscribers on the sector controller.
The procedures in this section must be used when changing the CIR / PIR settings on
services associated with STID link templates. This procedure is not required for
changing any other Link, Service, or Group CIR or PIR settings.
7.1.1

Modify STID CIR / PIR Silently (No Reboot)

Use this procedure to modify CIR/PIR settings for services on STID link templates
without rebooting the sector controller. This procedure modifies removes the current
STID link template and all associated services, and then creates a new link template
with identical name and password settings, and new services with the required CIR / PIR
settings. It is important to record all link and service settings before deleting the current
STID link template and services.
Note; During this procedure, all subscribers using the STID link template being modified
will be disconnected from the sector controller. These connections are restored
automatically following completion of the procedure. Other links are not affected.
Login to the sector controller Web interface.
1.
Select Provisioning -> Subscriber Links to view all links and identify the STID link
2.
with services that require changes to the CIR / PIR settings.
Click on the STID link name to view and record the current configuration settings for
3.
the STID link (e.g., use screen capture).
Click
4.
a. Click on the name of each service to view and record the current configuration
settings for each service (e.g., use screen capture).
b. Click on the trashcan ( ) adjacent to the service name to delete the service
(deletes service configuration).
c. Repeat (a) and (b) for all services associated with the STID link.
Click on the trashcan ( ) adjacent to the STID link name to delete the STID link
5.
(deletes the STID link template).
Select Provisioning -> New Subscriber Link to create a new STID link template.
6.
Select the link type to be 'Template' and configure all fields to be identical to the
STID link template settings saved in step 2. The STID name and STID password
must be identical to the original STID link. Save the new link template.
Select Provisioning -> New Subscriber Service to create a new service.
7.
Enter the new CIR / PIR settings. Configure the remaining fields to match the
configuration settings saved in step 3. Save the new service.
Repeat to re-create all the services used by the original STID link.
This completes the procedure. It is not required to reboot the sector controller.
Subscribers using this updated STID link template will reconnect automatically using the
new CIR / PIR settings following completion of the procedure.
70-00158-03-00
beside the STID link name to show all services associated with that link.