7.1.2
Modify CIR / PIR Settings in a Maintenance Window
Use this procedure to modify CIR/PIR settings for services on STID link templates during
a scheduled maintenance window when it is acceptable for the sector controller to be
taken offline for a short period. The operator must reboot the sector controller at the end
of the procedure.
Verify the maintenance window period is active.
1.
Login to the sector controller Web interface.
2.
Select Provisioning -> Subscriber Links to view all configured links.
3.
Identify the (STID) link with services requiring changes to the CIR / PIR settings.
4.
a) Click
b) Click on the name of a service to edit the service configuration and enter new CIR
/ PIR settings.
c) Save the modified service configuration.
Repeat step 4 as required to modify services for other STID templates.
5.
Reboot the sector controller to activate all changes.
6.
IMPORTANT: Failure to reboot the sector controller at the end of this procedure will
result in LOSS OF COMMUNICATIONS to all subscribers on the sector controller.
This completes the procedure.
7.2
ID Mapping
The following table lists the ID ranges assigned for each provisioning type.
Description
Links
Service Groups
Services
7.3
Radio Types
Type of radio installed. Refer to the Web General Information screen or CLI 'get
radiotype' command.
70-00158-03-00
USER MANUAL
to show all services associated with that link.
Table 31: Ref. - RDL-3000 ID Ranges
ID Range
4-127
128-159
160-511
Table 32: Ref. -RDL-3000 Radio Types
Radio Type
T072x
T212x
T202x
T352x
T502x
Proprietary Redline Communications © 2015
Total
124
32
352
Frequency Range (MHz)
470 - 698
2000 - 2300
2300 - 2800
3300 - 3800
4940 - 5875