Epson RC620 Manual page 31

Robot controller option, fieldbus i/o
Hide thumbs Also See for RC620:
Table of Contents

Advertisement

Specifications
Name
Part Number
Modes
Baud rates
Interface
Supported Devices
Maximum Nodes
Connection Types
Explicit Messaging
Connection
EDS Support
Max. Input Data Size
Max. Output Data Size
Automatic Detection
Modes
DeviceNet master board has the master mode and slave mode as motion modes. However,
do not select the slave mode.
Master mode
The master device gathers and controls all nodes on one network.
DeviceNet master can control up to 64 nodes (max. 128 bytes) in one network.
PLC is typically configured as a master and controls all nodes in factory automation
system, but EPSON RC+ is also capable of being a master.
DeviceNet network configuration is specified by configuration management software.
This is normally provided by a master device manufacturer.
management software determines parameters for each slave device via an Electronic Data
Sheet (EDS).
Available connection types are Polling, Strove, Cyclic, Change Of State, and Explicit
messaging.
Available baud rates are 125 kbps, 250 kbps, and 500 kbps.
For the setting instruction, refer to Master Mode later in this chapter.
RC620 Option Fieldbus I/O Rev.8
Item
DeviceNet master board
applicom PCI-DVNIO
Master
125, 250, 500 kbps
1 DeviceNet port
Group 2 Only Server and U.C.M.M. capable
63
Strobe, Polling, Cyclic and Change of State
Yes
Yes
1024 bits (128 bytes)
1024 bits (128 bytes)
Yes. Devices can be detected automatically.
Specification
The configuration
2. Installation
21