Problems And Countermeasures - Epson RC620 Manual

Robot controller option, fieldbus i/o
Hide thumbs Also See for RC620:
Table of Contents

Advertisement

4.2.2 Problems and Countermeasures

Light
OFF
Light
OFF
Light
OFF
Light
OFF
Light
OFF
Red
Light ON
RC620 Option Fieldbus I/O Rev.8
Master Unit LED
BF
ST
Green
Normal
Light
communication
Blinking
Green
Ready for
Light ON
communication
Red
Communication
Light
error
Blinking
Red
Data link layer
Light ON
error
Light
Uninitialized
OFF
network
No
Physical error
Matter
4. Troubleshooting (PROFIBUS DP)
Error
Description [Reference]
- Normal condition
- Normal condition
[Refer to the section 4.2.2.1 Master
Communication Error.]
- Slave disconnected from the network
(Remote I/O communication error)
- Slave not added to the network (Scan list
collation error)
- Nonstandard wiring
- No or too many terminating resistors
- Noise intrusion
[Refer to the section 4.2.2.2 Master: Data
Link Layer Error.]
- Nonstandard wiring
- Noise intrusion
[Refer to the section 4.2.2.3 Master:
Uninitialized Network.]
- Master unit power error
- Master unit configuration error
[Refer to the section 4.2.2.4 Master:
Configuration Error.]
- Nonstandard wiring
- Signal wire connection failure
- Signal wire short circuit
175

Advertisement

Table of Contents
loading

Table of Contents