2. Installation
NOTE
When Address Configuration is set to "DHCP/BOOTP/ARP", the controller waits for
DHCP/BOOTP/ARP sever response for 30 seconds at controller startup.
DHCP/BOOTP/ARP does not respond within the time, the Controller stops the request
to the DHCP/BOOTP/ARP server and waits ARP.
110
4. Select [Fieldbus Slave]-[General].
(4)
5. Make sure that the following are displayed.
Fieldbus Type : EtherNet/IP
Input Bytes
Output Bytes
6. Click <Close>.
7. Select [Fieldbus Slave]-[EtherNet/IP].
8. Set each item to the specific value to connect the Ethernet network.
For information about the setting values, contact your network administrator.
Address Configuration is set to "DHCP/BOOTP/ARP" at shipment.
9. When the configuration is completed, click <Apply> to apply the setting.
10. Click <Close>.
: 32 (default setting)
: 32 (default setting)
(5)
RC620 Option Fieldbus I/O Rev.8