4. Troubleshooting (DeviceNet)
4.1.3.6 EPSON RC+ Master Configuration
For details of EPSON RC+ master configuration, refer to the section 2.5 DeviceNet Board
Installation.
The following section describes the procedure for verifying the scanner board condition
with applicomIO Console application.
Verifying applicomIO Console application condition
The status bar at the bottom of the window shows the applicomIO Console application
status. The status bar varies as shown below:
Character
Background color : The background color indicates the scanner board status.
Background Character
Gray
Magenta
Red
Yellow
Dark green
Green
168
: The address number of the scanner board is indicated with
characters. When the character "F" appears, the flash memory on
the board initialized the scanner board.
For details, refer to the table below.
Black
Access to scanner board was failed.
After that, the status bar will not be renewed
automatically. To renew the status bar, right-click the
status bar and select Refresh.
Black
The scanner board was initialized with an earlier
version applicomIO Console application.
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner board)
again with the current version applicomIO Console
application.
Black
The scanner board was not initialized.
Initialize the scanner board to use it.
Black
The scanner board was partially initialized.
This status happens only during network detection and
on-line actions.
White
Although the scanner board was initialized, it is
different than the currently opened configuration.
(Different version, etc.)
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner board)
again with the current version applicomIO Console
application.
This status happens only during network detection, on-
line actions, and diagnostic.
Black
The scanner board was initialized properly and it is no
different with the currently opened configuration.
This status happens only during network detection, on-
line actions, and diagnostics.