14. Select [Fieldbus Master]-[Slaves].
15. Confirm that the following information the master controls is displayed.
2.1.4 DeviceNet Slave Board Installation
Appearance
RC620 Option Fieldbus I/O Rev.8
(14)
ID
: Fieldbus station ID of slave
Input Bytes
: Number of inputs per slave (Bytes)
Output Bytes : Number of outputs per slave (Bytes)
Spel Inputes : Number of inputs per slave (Bits)
Spel Outputs : Number of outputs per slave (Bits)
Status Display LED
Configure Switch
DeviceNet Connector
(15)
(15)
NS LED : Network status display
MS LED : Module status display
The LED shows the board status.
For details, refer to the section LED Description of
DeviceNet.
2. Installation
39