8 OUTPUT MODULE
(f) An example of an address mode clutch operation is shown below.
Operation example
1 axis
Virtual servomotor current value
(Synchronous encoder)
Current value within 1 virtual
axis revolution
Set the clutch status
Clutch ON address = 0
Clutch OFF address = 10000
Output axis current value
Current value within 1 output
axis revolution
(8) Current value within 1 virtual axis revolution storage device
(Auxiliary input axis side) (2 words)
This parameter is set when the address mode clutch is set at the rotary table
auxiliary input axis side.
Current value within 1 virtual
axis revolution
Address mode clutch
Set the clutch ON/OFF in this current value
(Current value within 1 virtual axis revolution).
1 axis
Number of pulses per revolution : 20000[PLS]
Drive module
8 - 18
0
0
10000
0
10000
0
20000
359.99999 [degree]
20000
10000
Drive module
Rotary table