8 OUTPUT MODULE

8.4.3 Parameter list

No.
Setting item
1
Output axis No.
Number of pulses per cam shaft revolution
2
(N
)
C
3
Cam No. setting device (1 word)
4
Permissible droop pulse value
5
Output unit
6
Stroke amount setting device (2 words)
7
Torque limit value setting device (1 word)
8
Comment
Lower stroke limit value storage device
9
(2 words)
Current value within 1 virtual axis revolution
10
storage device
(Main shaft side, 2 words)
Current value within 1 virtual axis revolution
11
storage device
(Auxiliary input axis side, 2 words)
The cam parameters are shown in Table 8.5 and the parameters No.2 to No.11 shown
in this table are explained in items (1) to (10) below.
Refer to the help of SW6RN-GSV22P for the cam parameter setting method.
Table 8.5 Cam Parameter List
(1) Number of pulses per cam shaft revolution (Nc)
(a) The number of pulses required to rotate the cam one cycle is displayed.
(b) The setting for the number of pulses per cam shaft revolution is not related
to the travel value per pulse (fixed parameter setting).
(2) Cam No. setting device (1 word)
(a) This device is used to set the device that sets in the Motion SFC program by
which the cam No. to control.
Default value
0
0
65535
mm
mm
None
Number of pulses per cam
shaft revolution (Nc)
8 - 29
Setting range
Q173CPU(N) : 1 to 32
Q172CPU(N) : 1 to 8
1 to 1073741824 [PLS]
Word device (D, W)
1 to 65535 [PLS]
inch
Word device (D, W)
-(300[%]) / word device (D, W)
32 characters
Word device (D, W)
- / word device (D, W)
- / word device (D, W)
PLS