4 POSITIONING DEDICATED SIGNALS
Error code
1
S/W fault 1
Operation cycle time over
2
Q bus WDT error
3
4
WDT error
Information processor H/W error
30
Q bus H/W fault
201
Error contents
201 to 215
01 : Q bus error 1
02 : Q bus error 2
04 : Q bus error 4
08 : Q bus error 8
Error code = Total of the error contents + 200
Servo amplifier interface H/W fault
250
Faulty SSCNET No.
250 to 253
0 : SSCNET 1
1 : SSCENT 2
2 : SSCNET 3
3 : SSCNET 4
Error code = Total of the faulty SSCNET No. + 250
300
S/W fault3
8 or more points of CPSTART instruction were used
to start programs in excess of simultaneously
startable program.
301
Number of simultaneous startable programs
During ROM operation, the system setting data,
302
programs and parameters written to internal FLASH
ROM are fault.
(2) Motion CPU WDT error cause (D9184) ............... Monitor device
This register is used as judgement of the error contents in the Motion CPU.
Error cause
14
Operation when error
occurs
All axes stop immediately,
after which operation
cannot be started.
4 - 84
Action to take
• Reset with the reset key.
• If the error reoccurs after resetting,
1) Change the operation cycle into
a large value in the system setting.
2) Reduce the number of command
execution of the event task or NMI
task in the system setting.
• Reset with the reset key.
• If the error reoccurs after resetting, the
relevant module or the relevant slot
(base unit) is probably faulty: replace
the module/base unit.
• Reset with the reset key.
• If the error reoccurs after resetting,
explain the error symptom and get
advice from our sales representaitive.
• Reset with the reset key.
• If the error reoccurs after resetting, the
relevant module or the relevant slot
(base unit) is probably faulty: replace
the module/base unit.
• Reset with the reset key.
• Reset with the reset key.
• Use 8 or more points of CPSTART
instruction to start programs within the
number of simultaneously startable
programs.
• Write the system setting data,
programs and parameters to the
internal FLASH ROM.