Mitsubishi Electric Q172CPU Programming Manual page 285

Motion controller, virtual mode
Hide thumbs Also See for Q172CPU:
Table of Contents

Advertisement

APPENDICES
Table 2.6 Output Module Error List (6000 to 6990) (Continued)
Output module
Error
Error
Ball
class
code Roller
screw
6160
Minor
error
6170
Output module
Error
Error
Ball
class
code Roller
screw
6500
Minor
6530
error
6540
Output module
Error
Error
Ball
class
code Roller
screw
9000
Minor
error
9010
Rotary
Cam
table
• Current value was changed for the axis
that had not been started. Or, the
current value within 1 cam shaft
revolution was changed for the servo
OFF axis.
• Slippage in-position range setting device
value is outside the range (0 to
2147483647).
(3) Clutch OFF and clutch OFF command output module errors
(6500 to 6990)
Table 2.7 Output Module Error List (6500 to 6990)
Rotary
Cam
table
• A servo OFF state at a clutch ON
command.
• The home position return request
signal (M2409+20n) is turning on at
a clutch ON command. (Incremental
axis servo amplifier power from off
to ON.)
• Although the feed current value is
within the stroke limit value, the
current value within 1 cam shaft
revolution cannot be calculated.
(Cam table error)
(4) System errors (9000 to 9990)
Table 2.8 Output Module Error List (9000 to 9990)
Rotary
Cam
table
• The motor type set in the "system
settings" differs from the motor
type installed at the turning on the
servo amplifier. (Check when MR-
J2S- B/MR-J2- B is used only.)
• The motor travel value while the
power is off exceeded the "System
setting mode-allowable travel value
during power off" set in the system
settings at the turning on of the
servo amplifier.
Error cause
Error cause
Clutch remains OFF.
Servo remains ON.
Error cause
Further operation is
possible.
Virtual mode
continuation operation
disable warning signal
turns on.
Further operation is
possible.
APP - 40
Processing
Corrective action
Do not change
• Use the following device as
the current
interlock not to change the
value within 1
current value for applicable axis.
cam shaft
(Servo READY signal
revolution.
(M2415+20) ON)
Control with the
• Set the device value within the
setting value
range of 0 to 2147483647.
"0".
Processing
Corrective action
• Return to the clutch OFF
command, and repeat the
clutch ON command after
executing a servo ON
command.
• Return to the real mode, back
to the virtual mode after
home position return.
• Return to the real mode,
correct the cam data settings.
• Set the cam table by the
stroke ratio "0 to 7FFFH" of
lower stroke value and stroke
amount.
Processing
Corrective action
• Correct the motor type
setting in the system
settings.
• Check the position.
• Check the battery of
encoder.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec q seriesSv22Q173cpuQ172cpunQ173cpun

Table of Contents